Siemens, Loadcenter, S1224B1100 (Old Part# G1224B1100)

Siemens, Loadcenter, S1224B1100 (Old Part# G1224B1100)

Convertible/Main Breaker, 100A, 1 Phase, 3 wire, 12 Spaces, 24 Circuits, Aluminum Bus, Indoor

SKUM29309
ManufacturerSiemens
Mfr. Part #S1224B1100 / G1224B1100
UPC040892650853
Points0.70
$69.81
   
Related Categories
Applications
  • Copper load centers are recommended for those applications where the environment may be severe, (i.e. farm and coastal areas) or where a premium panel is desired
  • Prepositioned bond screw should be driven down prior to installation of load center in surface mount applications
  • Excluding AFCI, GFCI, and surge breakers
  • G1224L1125CUSG has 83% neutrals and grounds
  • NEC is a registered trademark of the National Fire Protection Association
Features
  • UL Listed
  • INSTA-WIRE™ neutrals, grounds, and circuit breakers provide quick conductor installation
  • Visible neutrals aid in conductor installation
  • Combination slot/square head screws
  • Factory installed ground bars on all main lug load centers
  • Pre-positioned bond screw makes bonding a snap
  • All devices convertible from main lug to main breaker and vice-versa
  • All factory installed main breakers are bolt on, straight in wired
  • All load centers are invertible for bottom feed applications
  • Lifetime warranty on Siemens installed circuit breakers
  • Trim mounting tabs free up both hands to install the trim
  • Tangential knockouts eliminate the need for conduit offsets
  • Combination flush / surface mount trim
  • The ¡®SG¡¯ line of main lug load centers come with a 100% provision neutral and a 100% provision ground
  • The ¡®SG¡¯ load centers come with a neutral tie strap which allows crsion to service entrance equipment
  • The side-hinged door on the outdoor load center can be removed by backing out only one screw
  • Type QP, QPH, and HQPH circuit breakers can be used as backfed mains on any Ultimate Load Center when used in conjunction with MBR2 hold down kit
  • The neutral tie strap on Ultimate Load Centers can be removed to convert the left neutral bar into a ground bar, and to isolate the right neutral bar
  • A lug kit, LKB1 is required for this type of installation
  • The INTS, insulated neutral tie strap, is not needed on Ultimate Load Centers
  • The neutrals and grounds in the Ultimate Load Center are NEC and UL approved to accept multiple ground conductors
  • Load centers do not have fire ratings for use in firewalls
Downloads
Specification
Trade Name Ultimate® Load Center
Main Type Convertible/Main Breaker
Phase Single
Wire 3
Ampere Rating (A) 100
Voltage Rating 120/240VAC
Enclosure Type NEMA 1 (Indoor)
Short Circuit Current Rating (kA) 22
Number of Spaces 12
Number of Circuits 24
Max. 2 Pole 6
Mounting Type Plug-In
Cover Type Combination
Bus Material AL
Height (In.) 18
Width (In.) 14.31
Depth (In.) 3.94
Standards UL Listed